Generate Oxygen at less than one third cost of
oxygen from cylinders. Oxygen Available directly in gaseous form, Flow can
be achieved from 1-300 Nm3/hr.
Process
Compressed air from air compressor is passes through filtration unit to
remove the moisture and dust particles. Main adsorption system consists of
two adsorbers with synthetic Zeolite (Molecular Sieve) inter connected
through changeover valves. At a time one adsorber remains in adsorption and
generate the oxygen, while the second is regenerated by purging. Once the
regeneration of the second adsorber is completed, there would an automatic
changeover and cycle is reversed.
Features
- Simplicity & compact Design
- Fully automatic & safe
- Safe Operation, Low working Pressure
- Ambient Temperature Operation
- Need Only electrical power and cooling water